Circulation Pump Failures and Solutions

What Is a Circulation Pump?
A circulation pump is the pump that enables hot water to circulate within the piping system in heating systems.
Thanks to these pumps:
- water heated in the combi boiler or boiler
- to the radiators
- to the underfloor heating pipes
is delivered, ensuring heat distribution at every point of the system.
The most commonly used pump brands are:
- Grundfos circulation pumps
- Wilo circulation pumps
- DAB pumps
- Lowara pumps
- Ebara pumps
Choosing the right pump and performing regular maintenance prevents pump failures.
For the most reliable models, the Magna1 25-100 and Magna1 25-120, you can visit our products.
Circulation Pump Failures
The most common failures encountered in circulation pumps are as follows.
1️⃣ Circulation Pump Not Working
This is one of the most frequently encountered pump failures.
Possible Causes
- the electrical connection may be cut off
- the pump motor may have burned out
- control board failure
- jamming of the pump rotor
Solution
First, the pump's electrical connection should be checked. If the pump does not turn, the rotor should be checked.
2️⃣ Pump Runs But Does Not Heat
This situation usually indicates that although the pump is running, water circulation is not taking place.
Possible Causes
- air in the piping system
- clogging of the strainer filter
- insufficient pump flow rate
- blockage in the piping system
Solution
The air should be bled from the system and the filter should be cleaned.
3️⃣ Pump Is Making Noise
If the pump makes noise while running, there may be a problem in the system.
Possible Causes
- air inside the pump
- bearing wear
- rotor balance problem
- air inside the piping system
Solution
The pump should be bled of air and the system should be checked.
4️⃣ Pump Runs Continuously
In some cases, the pump may run continuously.
Possible Causes
- thermostat failure
- control system error
- temperature sensor failure
Solution
The combi boiler's control system and sensors should be checked.
5️⃣ Pump Consumes Too Much Electricity
Older-type pumps can consume high amounts of electricity.
Possible Causes
- old pump model
- fixed-speed motor
- operating under high load
Solution
It is recommended to use a new-generation inverter pump.
6️⃣ Pump Is Vibrating
If vibration occurs while the pump is running, there may be a mechanical problem.
Possible Causes
- rotor imbalance
- bearing failure
- piping connection error
Solution
The pump installation should be checked.
7️⃣ Pump Is Overheating
Excessive heating of the pump may indicate a serious failure.
Possible Causes
- motor strain
- lack of water circulation
- mechanical jamming
Solution
The pump should be turned off immediately and checked.
The Most Widely Used Circulation Pump Models
The models most commonly used in residential and central systems are as follows.
Grundfos
- Grundfos Alpha2
- Grundfos Alpha3
- Grundfos Magna
Wilo
- Wilo Yonos PICO
- Wilo Stratos
- Wilo Star RS
DAB
- DAB Evosta
- DAB Evosta 2
These pumps are preferred for their energy efficiency and durability.
How Long Does a Circulation Pump Last?
The average lifespan of a quality circulation pump is:
8 – 15 years
and can vary within this range.
However, the following factors affect its lifespan:
- water quality
- cleanliness of the piping system
- pump brand
- maintenance condition
How to Choose a Circulation Pump?
The following criteria should be considered when choosing a pump.
- flow capacity
- head
- energy efficiency
- system type
Choosing the wrong pump can cause failures.
Conclusion
Circulation pump failures generally result from the following causes:
- air in the piping system
- filter clogging
- pump wear
- electrical issues
Early detection of these issues increases system efficiency and extends the pump's lifespan.